- All products are added to your cart.
Johnson circulation pump CombiLine CL 32-125
CL 32-125 0,13kw
Johnson circulation pump CombiLine CL 32-125
Johnson circulation pump CombiLine CL 32-125
-
Description
Johnson circulation pump CombiLine CL 32-125
In-line circulation pump with dry motor. The CombiLine is suitable for handling low-viscosity, clean or slightly contaminated liquids in heating and cooling systems. Suction and discharge connections are “in-line” allowing easy installation in piping system.
Pump specifics- Compact and modular design
- With mechanical seal
- Dry shaft construction by means of shaft sleeve
- Closed impeller
- Specially designed low NPSH suction inlet casing;
- Vertical and Horizontal mounting (floor and wall)
Technical data
- Pump casing: Cast iron
- Impaller: cast iron
- Maximum capacity: 400 m3/h
- Maximum delivery head: 28 m
- Maximum temperature: 140°C
- Maximum operating pressure: 6-10 bar
- Nominal motor speed: 1 450 rpm
- Motor voltage 230/400V 50HZ
In the attached pdf you will find more technical information.
In our webshop we have included a selection of these pumps, see table below.
On request we can also supply pumps with other specifications, such as different diameter, impeller diameter, motor power, special voltage/speed and 2- and 6-pole pumps.Type Motor kw ND NW IEC CL 32-125 0.13 ND 6 32 63 CL 40C-125 0.13 ND 6 40 63 CL 40C-125 0.18 ND 6 40 63 CL 40C-125 0.25 ND 6 40 71 CL 40C-125 0,37 ND 6 40 71 CL 40-160 0.25 ND 6 40 71 CL 40-160 0.37 ND 6 40 71 CL 40-160 0.55 ND 6 40 80 CL 50-125 0.25 ND 6 50 71 CL 50-125 0.37 ND 6 50 71 CL 50-160 0,25 ND 6 50 71 CL 50-160 0.37 ND 6 50 71 CL 50-160 0.55 ND 6 50 80 CL 65-125 0.25 ND 6 65 71 CL 65-125 0.37 ND 6 65 71 CL 65-125 0.55 ND 6 65 80 CL 65-160 0.55 ND 6 65 80 CL 65-160 0.75 ND 6 65 80 CL 65-160 1.1 ND 6 65 80 CL 80-125 0.55 ND 6 80 80 CL 80-125 0.75 ND 6 80 80 CL 80-125 1.1 ND 6 80 90 CL 80-160 1.1 ND 6 80 90 CL 80-160 1.5 ND 6 80 90 CL 80-160 2.2 ND 6 80 100 CL 100-150 0.75 ND 6 100 80 CL 100-150 1.1 ND 6 100 90 CL 100-150 1.5 ND 6 100 90 CL 100-160 1.5 ND 6 100 90 CL 100-160 2.2 ND 6 100 100 CL 100-160 3 ND 6 100 100 CL 125-160 1,5 ND 10 125 100 CL 125-160 2.2 ND 10 125 100 CL 125-160 3 ND 10 125 100 CL 125-160 4 ND 10 125 112 CL 125-160 5,5 ND 10 125 132 CL 125C-200 4 ND 10 125 112 CL 125C-200 9,20 ND 10 125 132 This product is supplied without gaskets, flanges and nuts and bolts.
One gasket is required per flange.Brochure Johnson Horticulture Circulation pumps (EN)
-
Johnson circulation pump CombiLine CL 32-125
In-line circulation pump with dry motor. The CombiLine is suitable for handling low-viscosity, clean or slightly contaminated liquids in heating and cooling systems. Suction and discharge connections are “in-line” allowing easy installation in piping system.
Pump specifics
- Compact and modular design
- With mechanical seal
- Dry shaft construction by means of shaft sleeve
- Closed impeller
- Specially designed low NPSH suction inlet casing;
- Vertical and Horizontal mounting (floor and wall)
Technical data
- Pump casing: Cast iron
- Impaller: cast iron
- Maximum capacity: 400 m3/h
- Maximum delivery head: 28 m
- Maximum temperature: 140°C
- Maximum operating pressure: 6-10 bar
- Nominal motor speed: 1 450 rpm
- Motor voltage 230/400V 50HZ
In the attached pdf you will find more technical information.
In our webshop we have included a selection of these pumps, see table below.
On request we can also supply pumps with other specifications, such as different diameter, impeller diameter, motor power, special voltage/speed and 2- and 6-pole pumps.
Type | Motor kw | ND | NW | IEC |
CL 32-125 | 0.13 | ND 6 | 32 | 63 |
CL 40C-125 | 0.13 | ND 6 | 40 | 63 |
CL 40C-125 | 0.18 | ND 6 | 40 | 63 |
CL 40C-125 | 0.25 | ND 6 | 40 | 71 |
CL 40C-125 | 0,37 | ND 6 | 40 | 71 |
CL 40-160 | 0.25 | ND 6 | 40 | 71 |
CL 40-160 | 0.37 | ND 6 | 40 | 71 |
CL 40-160 | 0.55 | ND 6 | 40 | 80 |
CL 50-125 | 0.25 | ND 6 | 50 | 71 |
CL 50-125 | 0.37 | ND 6 | 50 | 71 |
CL 50-160 | 0,25 | ND 6 | 50 | 71 |
CL 50-160 | 0.37 | ND 6 | 50 | 71 |
CL 50-160 | 0.55 | ND 6 | 50 | 80 |
CL 65-125 | 0.25 | ND 6 | 65 | 71 |
CL 65-125 | 0.37 | ND 6 | 65 | 71 |
CL 65-125 | 0.55 | ND 6 | 65 | 80 |
CL 65-160 | 0.55 | ND 6 | 65 | 80 |
CL 65-160 | 0.75 | ND 6 | 65 | 80 |
CL 65-160 | 1.1 | ND 6 | 65 | 80 |
CL 80-125 | 0.55 | ND 6 | 80 | 80 |
CL 80-125 | 0.75 | ND 6 | 80 | 80 |
CL 80-125 | 1.1 | ND 6 | 80 | 90 |
CL 80-160 | 1.1 | ND 6 | 80 | 90 |
CL 80-160 | 1.5 | ND 6 | 80 | 90 |
CL 80-160 | 2.2 | ND 6 | 80 | 100 |
CL 100-150 | 0.75 | ND 6 | 100 | 80 |
CL 100-150 | 1.1 | ND 6 | 100 | 90 |
CL 100-150 | 1.5 | ND 6 | 100 | 90 |
CL 100-160 | 1.5 | ND 6 | 100 | 90 |
CL 100-160 | 2.2 | ND 6 | 100 | 100 |
CL 100-160 | 3 | ND 6 | 100 | 100 |
CL 125-160 | 1,5 | ND 10 | 125 | 100 |
CL 125-160 | 2.2 | ND 10 | 125 | 100 |
CL 125-160 | 3 | ND 10 | 125 | 100 |
CL 125-160 | 4 | ND 10 | 125 | 112 |
CL 125-160 | 5,5 | ND 10 | 125 | 132 |
CL 125C-200 | 4 | ND 10 | 125 | 112 |
CL 125C-200 | 9,20 | ND 10 | 125 | 132 |
This product is supplied without gaskets, flanges and nuts and bolts.
One gasket is required per flange.
Brochure Johnson Horticulture Circulation pumps (EN)